We'd value your feedback. Click here...
Saving and Restoring the Software Settings
Use this option to save your configuration to a USB stick or restore a previously saved file:
-
Insert a memory stick into the USB 2.0 (A) connector. See table in Main Station/Remote Station: Front panel
-
In Menu mode, select Administration and then Settings.
-
To save, in the third menu, select Save All. Once you select Save you should not remove the USB stick right away. Depending on the USB stick it might take up to 5 seconds to complete.
-
To restore all HMS settings, in the third menu, select Restore all.
-
In the fourth menu, select a file from USB.
-
This restores the Helixnet Base, the Role and the Channel settings from the USB stick to your system.
-
-
To restore Roles and Channel names only, in the third menu, select Restore Role/Ch.
-
In the fourth menu, select a file from USB.
-
This restores Role and Channel settings from the USB to your system. Network settings are NOT restored.
-
Type of Save |
Result |
---|---|
Save All | Saves your whole configuration; Main Station, Remote Stations, Speaker Stations, Roles/Channel names to the USB for future use. This option also saves 2-wire and 4-wire port settings and assignment. |
Restore All |
Restores all settings from the file stored on the USB. |
Restore Role/Ch |
Restores Channel names and Role configuration only from the file stored on the USB. Network settings (including Linking and Expansion) are NOT saved. |